Optimizing tempdb and log disk performance

We implemented a new SAN fairly recently: an HP EVA. In the enthusiasm to move to this new device, some tuning decisions were overlooked or made quickly, and are now being revisited. For example, all the drives allocated to database servers were created on VRAID5 (essentially equivalent to RAID 5, refer to HP's IT Resource Center for the nuances).

In general, it's a known fact that RAID 10 (aka VRAID1) outperforms RAID 5 (aka VRAID5) for write-heavy workloads, but at a higher cost per GB. I wanted to revisit the cost-benefit analysis that led us to use RAID 5, because I've always used RAID 10 for at least logs and tempdb in the past, and for all SQL data when possible.

To make sure that my analysis was relevant to our particular IO load, I planned to generate load on each type of drive using IOMeter, for which I would need to construct an appropriate workload. I recorded a Counter Log with the following counters from each drive using Windows Performance Monitor from our main OLTP server over the course of several days.
  • Avg Disk Bytes/Read
  • Avg Disk Bytes/Write
  • Avg Disk Queue Length
  • Disk Reads/sec
  • Disk Writes/sec
Using these counters, I constructed a characteristic workload for each drive.

To do this, I first bucketed each reading of Avg Disk Bytes/[Read, Write] into a size category (.5K, 1K, ...64K, 128K, etc.) and chose enough categories to add up to 80% of the total in order to determine what size IOs to generate.

Then I added the averages of Disk Reads/sec and Disk Writes/sec in order to get the percentages of reads and writes against each disk, and used the average of Avg Disk Queue Length to determine how many IOs outstanding to queue up.

Finally, I ran through this whole exercise again after deciding to filter for Disk Queues > 2. I did this because I figured that the SAN probably wasn't having any trouble when disk queues were low - RAID 5 vs RAID 1 would only show a difference in latency during those times. The trouble comes when loads (for which disk queues are a proxy) are high; that's when you need maximum throughput and minimum response time.

After all this, I came up with the following characteristic workloads for our system (yours may vary substantially):

TEMPDB
Reads - 2%
- 68% 64K read size
- 32% 8K read size
Writes - 98%
- 83% 64K write size
- 17% 512B write size
600 IOs outstanding

LOGS
Reads - 36%
- 87% 128K read size
- 13% 1024K read size
Writes - 64%
- 81% 64K write size
- 19% 16K write size
4 IOs outstanding

Next I worked with our Systems Engineering group to create a VRAID5 and a VRAID1 drive of the same size and attached both to the same server. I created Access Specifications with IOMeter for each workload shown above (see image below), and then ran those Access Specifications against each drive with the requisite number of IOs outstanding.

This yielded some fairly conclusive results. I won't post the actual throughput numbers, but here are the margins by which VRAID1 outperformed VRAID5 for each workload:

TEMPDB
IOPS MB/s Avg IO Response Time
117.65% 117.55% 51.48%

LOGS
IOPS MB/s Avg IO Response Time
80.05% 65.63% 39.69%

So according to my testing, VRAID1 is vastly superior for these types of workloads, to the point where it's probably worth the higher cost per GB. We'll see how this bears out in further testing and in real-world usage shortly...

Wednesday, May 16, 2007

WRITELOG waits

My team has been assisting another team off and on for several months with performance tuning their overnight DB processes. There are many possible bottlenecks in their process, but since the app writing into the DB is highly complex and multi-tiered, we're trying to focus on the internal DB issues first.

The first big win was dropping triggers from the tables being written to, which resulted in a 20% reduction in overall job time. Now the biggest WAITTYPE during the process is WRITELOG, with about 50-60% of the overall time in both QA and Prod. NETWORKIO is next, and I'd really like to SET NOCOUNT ON, since these writes are created as individual transactions and dropping the count should reduce the NETWORKIO substantially, but that's been problematic so far.

Digging into the WRITELOG waits, the disk queues are pretty low (0-5 range going against 80 or so physical disks on a big Hitachi SAN with a ton of cache), so the storage guys have dismissed the disk as the problem. However, I think it's still the disk, just not in the usual way.

The standard problem is that the disk subsystem runs out of write cache and has to start de-staging data to disk, and the physical disks can't write data as fast as it's coming in. That's not the case here, because the cache on the SAN is huge (70+ GB, according to the SAN guys), it can accept data faster than the logs are created, and it hasn't gotten close to the high watermark, when it starts de-staging. So what's the problem?

Well, in this case, the disks attached to the SQL Server have been attached as a single logical drive, so all the IOs get queued by Windows against that drive. Therein lies the problem, I believe. The SAN is fast, but every operation goes against that same queue, so one slow read for a piece of data not in the cache can slow down all the writelog IOs queued up behind it. This is what I believe is creating the WRITELOG waits.

The proposed solution is simple: add another logical drive dedicated to logs. Even if it's hitting the same physical disks, the addition of another disk queue should allow the log IOs to flow through without being blocked by slower data IOs or data reads. Stay tuned to see if it works.

Addendum: We tried this before at Capital IQ, splitting up sets of disks into multiple metaLUNs and comparing them against the same number of disks in one metaLUN and showed barely any performance gain (within the margin of measurement error). However, the difference between that situation and this one was the amount of cache involved - we were always past cache on the CapIQ SAN, so the disks were the bottleneck. Here I suspect it's the queue.